The solar collector is complete with all 30 tubes installed and producing heat energy for the first full day.
Solar SR868C8 Display Showing Collector Temperature
Installing Evacuated Vacuum Tube: Robert and Ian Installing Evacuated Vacuum Tube and sanding the evacuated copper end before adding thermal/anti-seize paste
Thermal Vacuum Collector: Beautiful solar day to work
Solar Vacuum Tube Collector
Installing the last Tube
Finished and Operational Solar Collector
The following charts shows the results in Fahrenheit . In the afternoon around 3 pm (15:00) all the tubes were in.
Time |
T1 on Collector |
T2 on Coil in Tank |
T3 on Top of Tank |
|
10:15 |
132 |
109 |
96 |
|
11:15 |
140 |
118 |
104 |
|
13:30 |
149 |
134 |
120 |
|
14:45 |
179 |
138 |
123 |
|
15:05 |
186 |
140 |
122 |
|
15:40 |
172 |
141 |
125 |
|
17:00 |
163 |
147 |
131 |
|
18:45 |
114 |
141 |
131 |
Still have more testing to do and a few more advances. One, install the air purge again and see if we can get it to not leak liquid and not suck in air like it did before. Second, began the office air space solar heat exchanger and see if we can wire it up to the solar controller.